Lovibond® Water Testing Tintometer® Group

MD 100 PoolControl 3in1

Stock Code
278011

Product Name
MD 100 PoolControl 3in1

Test / Range

Chlorine 0-6.0 mg/l
pH Value 6.5-8.4
Cyanuric Acid 2-160 mg/l





  • Picture 1


The MD 100 PC 3in1 portable handheld instrument is ideal for regular testing of the most popular pool parameters.

Simple button layout, robust waterproof design and backlit display make it suitable for use poolside or in the Plant Room.

The units supply accurate, reproducable results using high quality interference filters with long-life LEDs as a light source. Tests are conducted using Lovibond® tablet reagents which give long-term stability and a guaranteed minimum 5 or 10 year shelf life. Liquid reagents can also be used.

Test results are automatically stored with time and date for later review, and can also be downloaded to a PC using an additional Infra Red interface.

Additional Features:

Scroll Memory (SM)
To avoid unnecessary scrolling for the required test method, the instrument memorises the last method used before switching off. When the instrument is switched on again, the last used test method is selected automatically.
  Zero Setting (OTZ)
Certain instruments have a One Time Zero (OTZ) function, making it unnecessary to zero the instrument between each test. This allows multiple tests to be performed using water from the same body of sample water until the instrument is turned off.
Calibration certificate
Beside the "Certificate of Compliance" which is supplied with the MD 100, calibration certificates are available at cost on request. Individually supplied per instrument and per method, The Calibration Certificate must be ordered on initial purchase of the instrument.
  N.I.S.T Traceability
The instrument has a factory calibration, which is related to international standards which are not N.I.S.T traceable. The instrument may be calibrated by the user in a "user calibration mode" with N.I.S.T traceable standards.
(N.I.S.T. = National Institute of Standards and Technology)
Data transfer
The optional available IRiM (infra-red interface module) uses infra-red technology to transmit test data from the MD 100 to one of 3 interfaces. Data can be downloaded to a PC or directly printed using a USB printer or serial printer connected to the IRiM module.
The unit is supplied complete with data logging software providing easy and rapid transfer of data to the PC. Data can be saved as an Excel sheet or a .txt file.
  Verification Standard Kit
The Verification Standard Kit for the MD 100 is designed to reassure the user about the accuracy and the reliability of the results.
The shelf life of the Verification Standard Kit is two years from the date of production, provided that storage and use are in accordance with the instructions provided.
Verification Standard Kit 215670

 

  • Instrument in carrying case
  • 4 Micro batteries (AAA)
  • 3 Round vials (Glass) with lids
  • Tablets reagents
  • Crushing / Stirring Rod
  • Guarantee sheet
  • Certificate (COC)
  • Instruction manual 
  Optics   LEDs, interference filters (IF) and photo sensor in transparent sample chamber.
Depending on the version, up to 3 different interfernce filters are used.
Wavelength specifications of interference filters:
430 nm Δ λ = 5 nm
530 nm Δ λ = 5 nm
560 nm Δ λ = 5 nm
580 nm Δ λ = 5 nm
610 nm Δ λ = 6 nm
660 nm Δ λ = 5 nm
  Wavelength Accuracy   ± 1 nm
  Photometric Accuracy   3% FS (T = 20°C - 25°C)
  Power Supply   4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests
  Auto - OFF   automatic switch-off
  Display   backlit LCD (on keypress)
  Storage   internal ring memory for 16 data sets
  Interfaces   infrared interface for test data transfer
  Additional feature   real time clock and date
  Calibration   factory calibration and user calibration. Reset to factory calibration possible
  Dimensions   155 x 75 x 35 mm (L x W x H)
  Weight   basic unit approx. 260 g
  Environmental conditions   temperature: 5 - 40 °C rel. humidity: 30 -90% (non condensing)
  Conformity   CE; tested with standard solutions

 

Stock Code

Reagent

Test

Qty


511050BT

DPD No 1 Tablets

Chlorine

100

511051BT

DPD No 1 Tablets

Chlorine

250

511770BT

Phenol Red Photometer Tablets

pH Value

100

511771BT

Phenol Red Photometer Tablets

pH Value

250

511370BT

Cyanuric Acid CyA-Test Tablets

Cyanuric Acid

100

511371BT

Cyanuric Acid CyA-Test Tablets

Cyanuric Acid

250

511080BT

DPD No 3 Tablets

Chlorine

100

511081BT

DPD No 3 Tablets

Chlorine

250


Stock Code

Name


197629

Photometer Cell ø 24mm with lid, pack of 5

364120

Crushing / Stirring Rod, pack of 10

275650

Reference Standard Kit, MD 100/200 Chlorine T

275670

Reference Standard Kit, MD100/200 pH

380230

Vial Cleaning Brush, short

170500

Pool Water Sampler


Choose a parameter