Test / Range

Aluminium 0.01-0.25 mg/l
Chloride 0.5-20 mg/l
Copper 0.3-5.0 mg/l
DEHA 20-500 µg/l
Hydrazine 50-500 µg/l
Iron 0.03-2.00 mg/l
Oxygen Saturation 10-800 µg/l
Phosphate 5-80 mg/l
Polyacrylate 1-30 mg/l
Silica 1-90 mg/l





  • Picture 1


A dedicated Lovibond® Photometer for Boiler Water

With one photometer to carry out all the tests associated with boiler water, plant managers no longer need to use multiple kits with up to 13 different pieces of equipment when one is now available.

The photometer has a dedicated range of application-specific tests. With the same degree of accuracy and repeatability, they are ideal for the operator who requires a multi-parameter instrument, without the need to invest in a high-end, all-encompassing product.  Combining additional tests for pH, conductivity and other titration tests such as alkalinity, hardness and sulphite, the user can request a complete analysis set, ideal for cooling system or boiler plant management.   

The photometer is supplied pre-calibrated with test methods, simply add the appropriate Lovibond® reagent sets (tablets, powder packs and liquids). Manufactured under tightly controlled conditions, sealed reagents have a shelf-life of up to 10 years since, until used, they are not exposed to the elements.

The MD 100 Boiler Water Photometer can be combined in a Build Your Own Test Kit with:

Compact Case
10 Plastic Tablet Boxes
Syringes
Crushing Rod
Titration Jar
Selected Reagents
Space for 2 x SD Meters
Space for Drop Test Reagents
 

  • Instrument in carrying case
  • 4 batteries (AA)
  • 3 Round vials (Glass) 24mm ∅ with lids
  • Crushing / Stirring Rod
  • Guarantee sheet
  • Certificate (COC)
  • Instruction manual

    Please note, reagents are not included with the standard package. The reagents that are available can be found under the respective tab.
  Optics   LEDs, interference filters (IF) and photo sensor in transparent sample chamber.
Depending on the version, up to 3 different interference filters are used.
Wavelength specifications of interference filters:
430 nm Δ λ = 5 nm
530 nm Δ λ = 5 nm
560 nm Δ λ = 5 nm
580 nm Δ λ = 5 nm
610 nm Δ λ = 6 nm
660 nm Δ λ = 5 nm
  Wavelength Accuracy   ± 1 nm
  Photometric Accuracy   3% FS (T = 20°C - 25°C)
  Power Supply   4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests
  Auto - OFF   automatic switch-off
  Display   backlit LCD (on keypress)
  Storage   internal ring memory for 16 data sets
  Interfaces   Infrared interface for test data transfer
  Additional feature   real time clock and date
  Calibration   factory calibration and user calibration. Reset to factory calibration possible
  Dimensions   155 x 75 x 35 mm (L x W x H)
  Weight   basic unit approx. 260 g
  Environmental conditions   Temperature: 5 - 40 °C rel. humidity: 30 -90% (non condensing)
  Conformity   CE; tested with standard solutions

 

Stock Code

Reagent

Test

Qty


535000

Aluminium Vario Powder Set

Aluminium

100

56R018490

Chloride Photometer Liquid Reagent Pack

Chloride

65ml

517691BT

Copper (No 1 & 2) Reagent Pack

Copper

100

536000

DEHA Vario Powder, Liquid Reagent Set

DEHA

200

462910

Hydrazine Test Powder, with spoon

Hydrazine

30g

56R018990

Iron LR Liquid Reagent Set

Iron

100

380450

Dissolved Oxygen Vacu Vial ® Reagent Set

Oxygen Saturation

30

56R019090

Phosphate HR Liquid Reagent Set

Phosphate

100

56R019165

Polyacrylate Liquid Reagent Set

Polyacrylate

100

535700

Silica HR Vario Powder Liquid Reagent Set

Silica

100


Stock Code

Name


197629

Photometer Cell ø 24mm with lid, pack of 5

364120

Crushing / Stirring Rod, pack of 10

380230

Vial Cleaning Brush, short

124060

Photometer Cleaning Set

214050

IRiM Data Module